Italy's 2020 radiation decree sets dose rules for CT and interventional units bought since August 2020, so our quotes check the dose features as well as the CE file. Send the model or specification, and we will set out those details, the Italian-language documents and sea freight into Genoa or another port you nominate.
Under Italy's 2020 radiation decree, a CT or interventional unit purchased after 27 August 2020 must display the dose at the end of each exam. It must also have systems to optimise dose and send dose data to the exam record. A practice must notify its medical X-ray equipment at least 10 days before it starts. Each X-ray unit is reported to ISIN, the national radiation inspectorate. These points shape a quote for X-ray and CT units in medical imaging, and they matter most for a pre-owned scanner.
We're MediGear, and we distribute medical equipment. Because our company is registered in England and Wales, we are not part of Italian hospital distribution: we quote supply from outside the EU. We work with healthcare buyers in more than 80 countries, from quote to freight. From a model number or clinical need, we find verified manufacturers that can supply hospital equipment in Italy with Italian documentation. Your engineers and procurement office see the quote only after we check the points on this page. The buyers page is where anyone buying for healthcare in Italy sends a request, and it requires no account.
Requests for Italy hospital supplies reach us from public trusts, research hospitals and private groups:
Under the 2023 procurement code, public procurement has used digital platforms since 1 January 2024. Consip runs Acquisti in Rete, which includes MePA, and most regions have their own central buyer. Publicly owned hospitals in Italy buy directly or through one of them. A private practice replacing a single ultrasound unit asks for a quote and compares, like any other buyer in the Italian healthcare system.
The Ministry of Health is the competent authority under Decree 137/2022, which brought Italian law into line with the EU Medical Devices Regulation. Information and instructions for users and patients must be in Italian when the device is delivered to the end user. Implant-card instructions must be in Italian and English. A distributor making devices available in Italy must register in the Ministry's national database, update changes within 30 days and confirm its data every two years.
Economic operators also register in EUDAMED. Under the regulation, the importer's role must be held in the EU, so who holds it when an Italian hospital buys straight from a UK supplier like us is for the hospital and its own advisers to determine. We are not an Italian importer or registered distributor, and we do not advise on regulation. Every quote still lists the certificates the unit holds.
Decree 101/2020 applies the EU safety standards, and ISIN, the national inspectorate for nuclear safety and radiation protection, runs the STRIMS register. A practice with medical X-ray equipment must notify the fire brigade, health-service bodies and the regional environmental agency at least 10 days before it starts. A prior authorisation, the nulla osta, applies to radiotherapy, nuclear medicine and mobile X-ray units of 200 keV or more.
Holders report the start and end of holding each unit through STRIMS. Medical users may report starts quarterly and ends once a year. Acceptance tests come before first use, then checks at regular intervals and after relevant maintenance, under a protocol from the medical physics specialist. Fluoroscopy without image intensification or dose-rate control is banned.
For diagnostic imaging devices, we ask the maker to confirm, in writing:
We put open questions to the maker in writing before quoting. A missing dose feature is hard to add once the unit is installed.
Customs is run by the Agenzia delle Dogane e dei Monopoli (ADM), under Decree 141/2024, which replaced the 1973 customs act in October 2024. An importer declares personally or through a customs representative, such as a registered customs broker. An operator not established in the EU must be represented by one that is. The documents per order:
The Servizio Fitosanitario Nazionale checks plant goods at 34 border control posts, 25 at ports and 9 at airports, and timber at most of them. Wood packaging from outside the EU must carry the ISPM 15 mark, and under EU rules, wood that fails is destroyed, sent back or treated. That is why we ask makers for crates marked to ISPM 15.
Our delivery point is the port or airport you nominate, where your customs representative handles the import declaration on your behalf, and the last leg is yours. Sicily and Sardinia have their own entry ports, such as Palermo, Catania and Cagliari.
A practice in Naples ordering one autoclave gets the same documented quote as a trust ordering forty, on most catalogue lines. A hospital opening a new ward can follow hospital setup, and labs can browse Lab, Pathology and Blood Bank for laboratory equipment. Pre-owned units are in our refurbished range. We found no Italian rule that bans refurbished medical devices, though the 2020 decree still sets conditions. A CT or interventional unit bought now must report and optimise dose, so an older model without those features may not be accepted. Every used X-ray unit also needs its 10-day notice, STRIMS reporting and an acceptance test.
General information is all this page offers Italian buyers: no offer to supply, and no legal, regulatory or customs advice. A quote reflects the maker's stock at the time, and an order binds both sides only once it is agreed in writing. Devices require Italian-language information, and medical X-ray devices require their notice and STRIMS reporting. Clearance and the regulatory position are matters for you and your customs representative, as we are not an Italian importer or distributor.
CT and interventional units bought in Italy since 27 August 2020 must report and optimise dose. Name the model and the site, with a data sheet if you have one, and we'll quote with the CE file, the dose features and the route.
Write to connect@medigear.uk or fill in the RFQ form on the buyers page, including a model number or specification; no account is required. We quote healthcare equipment and supplies in Italy for public trusts, IRCCS hospitals, private groups, dental and veterinary practices and distributors.
Yes. Information and instructions supplied with a device must be in Italian when it is delivered to the end user, and implant-card instructions must be in Italian and English. Before we quote medical diagnostic equipment, we check the maker's documents against these requirements and flag any gaps
Distributors that make devices available in Italy register there, update changes within 30 days and confirm their data every two years. Manufacturers, importers and authorised representatives register in EUDAMED, and registered operators that intend to supply the national health service may add device data to the database.
Normally, a notice is enough: the practice must notify the fixed diagnostic X-ray, CT included, at least 10 days before use unless a threshold in the decree applies. Radiotherapy, nuclear medicine, and mobile units of 200 keV or more require prior nulla osta. A CT unit acquired since August 2020 must also report and optimise dose.
Sea freight can go into Genoa, La Spezia, Livorno, Naples or Gioia Tauro, and smaller items can fly into Malpensa or Fiumicino. Sicily and Sardinia have their own entry ports. We deliver to the one you nominate, and the last leg is yours.
The importer can declare personally or through a customs representative, such as a registered customs broker, under the 2024 customs decree. An operator not established in the EU must be represented by one that is. Our part is the invoice, packing list, origin papers, HS codes and CE file.
Yes. One unit is quoted like any larger order on most catalogue lines, and a minimum order set by the maker shows up in our first reply. The practice reports the unit in STRIMS and notifies it at least 10 days before use.
That depends on the maker's stock, whether the unit is new or refurbished, and the sea leg, so name the deadline in your request. Each quote sets out the lead time and the route, and once the unit ships, we send updates by email.