Sale on Ophthalmic Equipment - Starting from 16 November!
In Japan, a device imported for sale must come in through a licensed marketing authorisation holder, so our quotes are written for that importer as well as for the clinical team. Send the model or specification, and we will set out the certificates, the 50 or 60 Hz build and sea freight into the Keihin or Hanshin ports.
Under Japan's PMD Act, importing a device in order to sell it counts as marketing. The importer must hold a marketing authorisation holder (MAH) licence. At the import declaration, customs asks for copies of that licence and of the model's approval, certification or notification. Power is the next check. The supply is 100 V, at 50 Hz in the east and 60 Hz in the west.
We're MediGear. Our company, registered in England and Wales, handles quotes, documents and shipping for healthcare buyers in more than 80 countries. For a Japanese order, we look for verified makers whose models hold Japanese approval or certification, or can reach you through your MAH. Then we check the points on this page before the quote reaches your engineers and buyers. A request needs nothing more than our buyers page, as there are no accounts.
Everyone in Japan has public medical insurance and a free choice of provider. Requests for Japan hospital equipment reach us from public hospitals in Japan, private groups and others, including:
Japanese government procurement notices are listed on the Digital Agency's site. Quoting through it needs the unified qualification and an electronic certificate. Among public medical institutions, the NHO publishes its own tenders and also runs joint tenders for medical equipment. A clinic replacing one ultrasound unit needs none of that, only a clear quote and an MAH to bring the unit in.
Devices in Japan fall under the PMD Act of 1960, which the Ministry of Health, Labour and Welfare (MHLW) runs. PMDA, the Pharmaceuticals and Medical Devices Agency, reviews products. Class I devices are notified to PMDA, and Class II and III devices are certified by a registered body where standards exist. Class IV needs MHLW approval, as PMDA's overview of device routes explains. A foreign maker markets through a Japanese MAH that it designates.
Selling or leasing X-ray, CT, MR and ultrasound units or bedside monitors needs a licence for each office, from the governor or a city mayor, renewed every six years. An MAH selling its own imports to licensed firms is exempt. Labels must be in Japanese, and package inserts can be searched on PMDA's website. A device without approval, certification or notification needs an MHLW import confirmation. A doctor or dentist may import up to three sets for their own patients. We hold no Japanese MAH or sales licence, so the regulatory side stays with your importer. The model's certificates are listed in every quote.
In Japan, we found no licence requirement to own or use diagnostic X-ray imaging equipment. Instead, the hospital or clinic manager notifies the prefectural governor within 10 days of installing a unit. Mobile and portable units count, as the Medical Care Act and MHLW's notice on medical radiation set out. The notice lists the maker, model, unit count, generator output, the shielding and the staff using it.
X-ray room walls, floor and ceiling must keep the dose outside at or below 1 mSv a week. The operating position normally sits outside the room. Radiation levels are measured once before clinical use, then at least monthly, or every six months for a fixed unit whose use and shielding stay the same. Records are kept for five years. Only physicians, dentists and radiological technologists may expose patients, and each hospital names a radiation safety lead who manages patient doses.
For a Japanese site, the maker must confirm:
Anything unclear goes to the maker in writing first, because a mains or frequency mismatch is hard to fix once the unit has landed.
The importer declares the goods at the customs office for the bonded area, usually through a customs broker licensed by the Minister of Finance. Filings go through NACCS online. Customs checks the PMD Act papers before it grants the import permit, so a file for Japan hospital supplies that are devices includes:
Japan has applied ISPM 15 to wood packaging since April 2007. The agriculture ministry's Plant Protection Station runs the checks, as its wood packaging page explains. If untreated wood carries quarantine pests, the whole lot must be treated or destroyed, or re-exported with permission. Makers are asked to ship in heat-treated crates that carry the stamp.
At the port or airport you nominate, your broker takes over with the import declaration, and the last leg is yours. Typhoons peak in August and September, so allow more time for summer sailings.
Single units are welcome, and most catalogue lines can be quoted for a clinic in Sapporo that needs just one monitor, or for a group buying medical equipment in Tokyo. Orders for Japan general hospital supplies follow the same route, and labs can send a data sheet for laboratory mixers or other laboratory equipment. For larger work, see hospital setup for new buildings, and maternity teams can browse Women, Children and Neonatal. Refurbished medical imaging equipment from our refurbished range can go to Japan, as no ban turned up, but only through a Japanese MAH whose approval covers the model. Before a used device is resold, the seller must notify that model's MAH and follow its instructions, which may include an inspection. Servicing in Japan needs a repair licence.
Read this as general information for Japanese buyers: it makes no offer to supply and gives no legal, regulatory or customs advice. Quotes depend on what makers can supply, and an order is agreed only in writing by both sides. Devices need a Japanese MAH and Japanese labelling, and an X-ray unit must be notified to the prefecture within 10 days of installation. Your importer handles clearance and the regulatory position, as we are not a Japanese MAH, importer or licensed seller.
Japan runs at 100 V, with 50 Hz in the east and 60 Hz from Chubu westward, so the factory build depends on the site. Send the model number or a data sheet and the prefecture, and we'll quote with the certificates, the MAH route and the sailing.
Yes. Hospitals in Japan, their MAHs, and distributors can send the request by email to connect@medigear.uk or through the RFQ form on the buyers page; no account is needed. We can quote healthcare equipment and supplies in Japan once we have the model or specification, quantity, and prefecture.
To import a device for sale, yes. Import for sale counts as marketing under the PMD Act, so the importer needs an MAH licence and the model needs approval, certification or notification. Doctors and dentists may import up to three sets for their own patients without import confirmation.
Japanese. The PMD Act's enforcement rules require label details in Japanese, and package inserts are published online, where anyone can search them on PMDA's site. We compare the maker's labelling with that rule before quoting and point out any gap.
Not as such. The hospital or clinic manager notifies the prefectural governor within 10 days of installation, including mobile units, and only physicians, dentists, and radiological technologists may expose patients. Radiation levels are then measured at set intervals and recorded for five years.
The Keihin ports of Tokyo and Yokohama and the Hanshin ports of Osaka and Kobe are the strategic international container ports, with Nagoya and Hakata as other options and Narita for air freight. You nominate the port or airport, and we deliver there.
Yes. Permits under other laws must be in place before customs grants the import permit, and copies of the MAH licence and the model's approval, certification or notification are shown at declaration. A licensed customs broker usually files on the importer's behalf.
It is. Most catalogue lines are quoted per unit, and we flag a maker's minimum order straight away. Even a single unit imported for sale has to come in through your MAH, so tell us who that is when you send the request.
They can. Typhoons peak in August and September, so summer sailings may need slack. Lead time also depends on the maker's stock, whether the unit is new or refurbished, and your MAH's paperwork, and the quote sets out the route and timing.