For hospitals in the United Kingdom, a medical device must be registered with the MHRA before it goes on the market in Great Britain, with labels in English, and X-ray work there needs registration with HSE. Our quotes set out the CE or UKCA marking, whether the unit ships from stock or from the maker, and the route.
In the United Kingdom, a device must be registered with the MHRA before it is placed on the market in Great Britain. A manufacturer based outside the UK needs a UK Responsible Person to register it, and labels and instructions must be in English. Great Britain accepts CE-marked devices until 30 June 2028 or 30 June 2030, depending on the device. Northern Ireland follows the EU regulation. So a quote for the United Kingdom starts with the marking and the registration.
Being registered in England and Wales makes MediGear a UK company. From here, we quote, document and ship medical diagnostic imaging equipment and other devices for healthcare buyers in more than 80 countries. For British hospitals, a unit may ship from stock or come from the maker abroad, and the quote says which. Your medical physics and procurement teams see it only once the points below are checked. Requests go through the buyers' page, with nothing to sign up for.
Across the four nations, our quotes go to UK hospitals and other buyers:
Public buying has followed the Procurement Act 2023 since 24 February 2025, with Find a Tender as the central platform. Devolved Scottish authorities sit outside most of it. NHS Supply Chain serves England and Wales, and National Procurement serves NHS Scotland. NWSSP serves the Welsh health boards, and BSO PaLS buys for health and social care in Northern Ireland. A single unit for a private clinic can be quoted from its model number, and so can a buyer of medical equipment in London.
The Medical Devices Regulations 2002, as amended, set the rules in Great Britain. Manufacturers register devices through DORS, and manufacturers outside the UK appoint a UK Responsible Person, who registers for them. A Great Britain-based importer must tell the manufacturer or UK Responsible Person that it intends to import. Medical device distributors in the UK that do not import need HRA registration. Since 16 June 2025, stronger post-market surveillance rules have applied. The manufacturer must keep a device safe for as long as it is in use.
Labels and instructions must be in English, and registrations appear in the MHRA's public database. In Northern Ireland, the EU regulation applies under the Windsor Framework, with CE marking and, where a UK notified body assessed the device, the UKNI mark. We give no regulatory advice, but each quote shows the marking, registration, and certificates behind the unit.
Under the Ionising Radiations Regulations 2017, HSE grades work with radiation in Great Britain as notify, register or consent. X-ray devices used by dentists, vets, chiropractors and NHS trusts need registration with HSE through its online service. Radiotherapy accelerators need consent. Northern Ireland has its own version of these rules, so United Kingdom X-ray apparatus in Northern Ireland follows the Ionising Radiations Regulations (Northern Ireland) 2017. Whoever erects or installs the unit must carry out a critical examination. They must also consult a radiation protection adviser and provide the user with information on use, testing, and maintenance.
For patient exposures from medical imaging equipment, IR(ME)R 2017 makes the employer test it before its first clinical use. Tests are repeated at regular intervals and after maintenance that can affect performance. Government guidance says staff the employer has designated and entitled should run the pre-use tests, not service engineers alone. CQC enforces in England, HIS in Scotland and HIW in Wales, and RQIA inspects under the Northern Ireland regulations. The equipment inventory must also record the year of manufacture and the year of installation.
For a UK site, the maker answers these first:
Anything still open goes to the maker in writing before the quote, because the registration and the installer's paperwork must match the unit.
For hospital equipment and supplies shipped from abroad, the import declaration goes through HMRC's Customs Declaration Service, often lodged by a customs agent. The importer needs a GB EORI number. With such an order, we send:
Solid wood packaging entering Great Britain from any country, including the EU, must meet ISPM 15, and the Forestry Commission's guidance says it may be checked at the border or inland. Wood that fails could be rejected or destroyed, so the crates we request from makers are heat-treated and stamped.
If the unit is imported, our delivery stops at the port or airport you choose, and your customs agent makes the import declaration. It goes into CDS, HMRC's Customs Declaration Service. Heathrow says it handles more cargo than all other UK airports combined.
A GP practice or care home can ask for one patient monitor, as most catalogue lines are quoted per unit. For laboratory equipment in a new pathology lab, see laboratory setup. Teams sourcing UK diagnostic imaging equipment can browse Medical Diagnostic Equipment. Our refurbished range can serve UK buyers, as no UK law bans the resale of used equipment. MHRA guidance expects anyone reselling used equipment to share usage and service history. Where UK refurbished medical equipment has only been reconditioned, the guidance also expects records of reconditioning and a decontamination certificate before the unit changes hands. A fully refurbished unit counts as placed on the market as new, and the refurbisher must affix a new mark.
The content here is general information for UK buyers. None of it is an offer to supply, and none of it is legal, regulatory or customs advice. Quotes depend on stock and the maker's lead times, and an order stands once both sides confirm it in writing. Devices need MHRA registration and English labels in Great Britain, and X-ray work there needs HSE registration and IR(ME)R testing. Customs clearance for imported units, HSE registration, and IR(ME)R checks remain with you and your agents.
Before a device goes on the market in Great Britain, it must be registered with the MHRA, and X-ray work there needs HSE registration. Name the unit and the site, and we will quote with the marking, the registration and the route.
Yes. NHS trusts and boards, private groups, practices and distributors can send a model number or specification through the RFQ form on the buyer's page or to connect@medigear.uk, as can other medical equipment and supplies suppliers. That includes a trust buying hospital equipment in London. Public tenders for United Kingdom hospital supplies follow each buyer's own procurement rules.
Yes, before it is placed on the market in Great Britain. The manufacturer registers it through DORS, or a UK Responsible Person does so for a manufacturer outside the UK. A Great Britain-based importer tells the manufacturer or UK Responsible Person, and UK medical device distributors that do not import need no registration.
Yes, for now. Great Britain accepts devices CE-marked under the old EU directives until 30 June 2028, or until their certificate expires if sooner, and EU MDR devices until 30 June 2030. A consultation on indefinite recognition closed in April 2026, and no outcome has been published.
The user of the equipment. In Great Britain, X-ray devices used by dentists, vets, chiropractors and NHS trusts need HSE registration through its online service. Radiotherapy accelerators need consent instead, and the installer must carry out a critical examination when it is fitted.
Testing before the equipment is first used on patients, performance testing at regular intervals and testing after maintenance that can affect performance. The law sets no fixed intervals, so your medical physics team sets them, and we send the maker's schedules with the quote.
Yes. Since 1 January 2021, solid wood packaging entering Great Britain from the EU, as from anywhere else, must be treated and marked to ISPM 15. Checks are risk-targeted, and wood that fails can be destroyed, so we ask makers for heat-treated, stamped crates.
Yes. A single unit is fine for most catalogue lines, including medical equipment for hospital wards, and if the maker sets a minimum order, our first reply says so. The lead time depends on whether the unit ships from stock or from the factory, and the quote says which applies.
Usually the paperwork: a missing MHRA registration, a marking close to its end date, HSE registration for X-ray equipment, or wood packaging without the ISPM 15 mark. The installer's critical examination and the pre-use tests also need to be booked before the unit goes into use.